PC-02 · BS 1881-204 / ACI 228.2R
Rebar / Ferro Scanning
Detect what's inside your concrete before drilling and coring.
OVERVIEWScope
Non-destructive rebar and ferro scanning to precisely locate reinforcement, cover depth, and post-tension before any coring or drilling — avoiding costly structural damage.
METHODTest method
Electromagnetic pulse induction (ferro scanner) with 2D/3D mapping.
PROCESSField protocol
- 01
Setup
Grid layout and reference marking on the target element.
- 02
Scan
Line and area scans capture rebar in both axes.
- 03
Map
Real-time 2D/3D rebar mapping on-device.
- 04
Certify
Interpretation signed and sealed by a licensed structural engineer.