PC-02 · BS 1881-204 / ACI 228.2R

Rebar / Ferro Scanning

Detect what's inside your concrete before drilling and coring.

OVERVIEWScope

Non-destructive rebar and ferro scanning to precisely locate reinforcement, cover depth, and post-tension before any coring or drilling — avoiding costly structural damage.

METHODTest method

Electromagnetic pulse induction (ferro scanner) with 2D/3D mapping.

PROCESSField protocol
  1. 01

    Setup

    Grid layout and reference marking on the target element.

  2. 02

    Scan

    Line and area scans capture rebar in both axes.

  3. 03

    Map

    Real-time 2D/3D rebar mapping on-device.

  4. 04

    Certify

    Interpretation signed and sealed by a licensed structural engineer.